Line

Description

 

 

 

 

 

 

Tx Bias Low

This can be either true or false, depending on the present Tx

 

Warning Flag

bias current value displayed above.

 

Tx Power Low

This can be either true or false, depending on the Current Tx

 

Warning Flag

power value displayed above.

 

 

Rx Power Low

This can be either true or false, depending on the Current Rx

 

Warning Flag

power value displayed above.

 

Example

Dell#show interfaces TengigabitEthernet 1/1 transceiver

 

SFP is present.

 

 

 

 

 

 

 

SFP 0 Serial Base ID fields

0x03

 

 

 

 

SFP 0 Id

 

=

 

 

 

 

SFP 0 Ext Id

 

=

0x04

 

 

 

 

SFP 0 Connector

 

=

0x07

 

 

0x01 0x20 0x40 0x0c

 

SFP 0 Transciever Code = 0x00 0x00 0x00

 

0x05

 

=

0x01

 

 

 

 

SFP 0 Encoding

 

 

 

 

 

SFP 0 BR Nominal

 

=

0x15

 

 

 

 

SFP 0 Length(9um) Km

=

0x00

 

 

 

 

SFP 0 Length(9um) 100m

=

0x00

 

 

 

 

SFP 0 Length(50um) 10m

= 0x1e

 

 

 

 

SFP 0 Length(62.5um) 10m

= 0x0f

 

 

 

 

SFP 0 Length(Copper) 10m

=

0x00

 

 

 

 

SFP 0 Vendor Rev

 

= A

 

 

 

 

SFP 0 Laser Wavelength

=

850 nm

 

 

 

SFP 0 CheckCodeBase

=

0x66

 

 

 

 

SFP 0 Serial Extended ID fields

0x12

 

 

 

SFP 0 Options

 

=

0x00

 

 

 

SFP 0 BR max= 0

 

 

 

 

 

 

 

SFP 0 BR min= 0

 

 

 

 

 

 

 

SFP 0 Vendor SN= P5N1ACE

=

040528

 

 

 

SFP 0 Datecode

 

 

 

 

SFP 0 CheckCodeExt

= 0x5b

 

 

 

 

SFP 1 Diagnostic Information

 

 

 

 

 

===================================

 

 

 

SFP 1 Rx Power measurement type

= Average

 

===================================

=

95.000C

 

SFP 1 Temp High Alarm threshold

 

 

SFP 1 Voltage High Alarm threshold

=

3.900V

 

SFP 1 Bias High Alarm threshold

 

=

17.000mA

 

SFP 1 TX Power High Alarm threshold

=

0.631mW

 

SFP 1 RX Power High Alarm threshold

=

1.259mW

 

SFP 1 Temp Low Alarm threshold

 

=

-25.000C

 

SFP 1 Voltage Low Alarm threshold

 

=

2.700V

 

SFP 1 Bias Low Alarm threshold

 

=

1.000mA

 

SFP 1 TX Power Low Alarm threshold

=

0.067mW

 

SFP 1 RX Power Low Alarm threshold

= 0.010mW

 

===================================

=

90.000C

 

SFP 1 Temp High Warning threshold

 

 

SFP 1 Voltage High Warning threshold

=

3.700V

 

SFP 1 Bias High Warning threshold

 

=

14.000mA

 

SFP 1 TX Power High Warning threshold

=

0.631mW

 

SFP 1 RX Power High Warning threshold

=

0.794mW

 

SFP 1 Temp Low Warning threshold

 

=

-20.000C

 

SFP 1 Voltage Low Warning threshold

=

2.900V

 

SFP 1 Bias Low Warning threshold

 

=

2.000mA

 

SFP 1 TX Power Low Warning threshold

=

0.079mW

Interfaces