Range from 0 to 5.
Defaults none
Command
Modes
EXEC Privilege
Command
History This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Added a warning message to the off-line diagnostic.
7.7.1.0 Introduced on the S-Series.
Usage
Information You cannot enter this command on a Master or Standby unit.
The system reboots when the off-line diagnostics complete. This reboot is an
automatic process. A warning message appears when the offline stack-unit
command is implemented.
Warning - Diagnostic execution will cause stack-unit to reboot
after completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
Related
Commands show environment (S-Series) — views the S-Series system component status (for
example, temperature, voltage).
online stack-unit
Place a stack unit in the online state.
Syntax online stack-unit number
Parameters number Enter the stack-unit number. The S6000 range is from 0 to 5.
Defaults none
Debugging and Diagnostics 525