Version Description
7.7.1.0 Removed three fields in the output: Vendor Name, Vendor
OUI, and Vendor PN.
7.6.1.0 Introduced on the C-Series and S-Series.
6.5.4.0 Introduced on the E-Series.
Usage
Information
The following describes the show interfaces transceiver command shown
in the following example.
Line Description
Rx Power
measurement
type
Output depends on the vendor, typically either “Average” or
“OMA” (Receiver optical modulation amplitude).
Temp High Alarm
threshold
Factory-defined setting, typically in Centigrade. Value differs
between SFPs and SFP+.
Voltage High
Alarm threshold
Displays the interface index number used by SNMP to
identify the interface.
Bias High Alarm
threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
TX Power High
Alarm threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
RX Power High
Alarm threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
Temp Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
Voltage Low
Alarm threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
Bias Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
TX Power Low
Alarm threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
RX Power Low
Alarm threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
Temp High
Warning threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
Voltage High
Warning threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
Bias High Warning
threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
TX Power High
Warning threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
718 Interfaces