Related Commands

VersionDescription

9.7(0.0)

Introduced on the S6000-ON.

8.3.19.0Introduced on the S4820T.

8.3.11.1Introduced on the Z9000.

8.3.7.0Introduced on the S4810.

Legacy E-Series command.

fefd — enables far-end failure detection.

fefd mode

Change the FEFD mode on an interface.

Syntax

fefd mode {normal aggressive}]

Parameters

Defaults

Command Modes

Command History

To return the FEFD mode to the default of normal, use the no fefd mode command.

normal

(OPTIONAL) Enter the keyword normal to change the link

 

state to “unknown” when a far-end failure the software

 

detects on that interface. When the interface is placed in

 

“unknown” state, the software brings down the line protocol.

aggressive

(OPTIONAL) Enter the keyword aggressive to change the

 

link state to “error-disabled” when a far-end failure the

 

software detects on that interface. When an interface is

 

placed in “error-disabled” state, enter the fefd reset

 

command to reset the interface state.

normal

 

INTERFACE

 

This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.

The following is a list of the Dell Networking OS version history for this command.

VersionDescription

9.7(0.0)

Introduced on the S6000-ON.

8.3.19.0Introduced on the S4820T.

8.3.11.1Introduced on the Z9000.

Layer 2

947

Page 947
Image 947
Dell 9.7(0.0) manual Fefd mode normal aggressive, Aggressive