fefd mode

Change the FEFD mode on an interface.

Syntax

fefd mode {normal aggressive}]

Parameters

Defaults

Command Modes

Command History

To return the FEFD mode to the default of normal, use the no fefd mode command.

normal

(OPTIONAL) Enter the keyword normal to change the link

 

state to “unknown” when a far-end failure the software

 

detects on that interface. When the interface is placed in

 

“unknown” state, the software brings down the line protocol.

aggressive

(OPTIONAL) Enter the keyword aggressive to change the

 

link state to “error-disabled” when a far-end failure the

 

software detects on that interface. When an interface is

 

placed in “error-disabled” state, enter the fefd reset

 

command to reset the interface state.