Example (All
Interfaces) systest-3 Monitor time: 00:01:31 Refresh Intvl.: 2s Time:
03:54:14
Interface Link In Packets [delta] Out Packets
[delta]
Te 0/0 Down 0 0 0 0
Te 0/1 Down 0 0 0 0
Te 0/2 Up 61512 52 66160 42
Te 0/3 Up 63086 20 9405888 24
Te 0/4 Up 14697471418 2661481 13392989657
2661385
Te 0/5 Up 3759 3 161959604 832816
Te 0/6 Up 4070 3 8680346 5
Te 0/7 Up 61934 34 138734357 72
Te 0/8 Up 61427 1 59960 1
Te 0/9 Up 62039 53 104239232 3
Te 0/10 Up 17740044091 372 7373849244 79
Te 0/11 Up 18182889225 44 7184747584 138
Te 0/12 Up 18182682056 0 3682 1
Te 0/13 Up 18182681434 43 6592378911 144
Te 0/14 Up 61349 55 86281941 15
Te 0/15 Up 59808 58 62060 27
Te 0/16 Up 59889 1 61616 1
Te 0/17 Up 0 0 14950126 81293
Te 0/18 Up 0 0 0 0
Te 0/19 Down 0 0 0 0
Te 0/20 Up 62734 54 62766 18
Te 0/21 Up 60198 9 200899 9
Te 0/22 Up 17304741100 3157554 10102508511
1114221
Te 0/23 Up 17304769659 3139507 7133354895
523329
m - Change mode c - Clear screen
b - Display bytes r - Display pkts/bytes per sec
l - Page up a - Page down
mtu
Set the link maximum transmission unit (MTU) (frame size) for an Ethernet interface.
S6000
Syntax mtu value
To return to the default MTU value, use the no mtu command.
Parameters value Enter a maximum frame size in bytes. The range is from 594
to 9252 for the S6000. The default is 1554.
Defaults 1554
Command
Modes
INTERFACE
Command
History This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
Interfaces 691