DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-320BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)]
9
Table 9-141. Test #619 BRI Port Local TDM Loop Around
Error
Code Test
Result Description/ Recommendation
1000 ABORT The system resources required to run this test are not available. The port
may be busy with a valid call.
1. Use the display port PCSSpp command to d etermine the station
extension or trunk group/m e mber number of the port . Use the status
bri-port PCSSpp command to determine the service state of the port. If
the service state indicates that the port is in use, then the port is
unavailable for certain tests. (Refer to the ‘‘Status Commands’’ section in
Chapter 8, ‘‘Maintenance Commands’’, for a full description of all
possible states.) Wait until the port is idle before retesting.
2. If the port is idle, then retry the command at one-minute intervals a
maximum of five times.
3. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic c onditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-ser vice.
1. Resolve any TTR-LEV errors
2. Resolve any TONE-PT err o rs.
3. If neither condition exists, retry the test at one-minute intervals a
maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a user for a valid call. Use the status station
command for the station associated with this port and determine when the
port is available for testing.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1005 ABORT This test is not valid for this type of translation. Ports administered as “ASAI”
or “ADJK” can not run this test, because the B channels associated with the
port are not used by ASAI or Lucent Adjunct Links. This is a normal
condition.
Continued on next page