DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1048MET-LINE (MET Line)
9
MET Circuit and Conference Circuit Test (#57)
This test checks two different por t circuit functions. The Hybrid Circuit test
performs an analog reflec tive looparound measurement on the p ort’s hybrid
circuitry. The Conference Circuit test perfor ms a conference test on the p ort’s
NPE.
For Hybrid Circuit Test results to be valid, a voice ter minal must be connected to
the port being tested . The test instructs the on-board microprocessor to p ut the
port in analog reflective loo paround mode. The Tone-Clock circuit p ack supplies
a 1004-Hz tone to the port’s listen time slot and a General Purpose Tone Detector
(GPTD) measures the level of the reflected signal app earing on port’s talk time
slot.
The Conference Test is performed only if the Hybrid Circ uit Test passes. The
Conference Circuit Test verifies that the Network Processing Element (NPE) is
able to correctly c onference several test tones together. The test is exec uted in
two parts. The first half of the test verifies operation of t he NPE’s first three
conference channels, and the second half verifies the NPE’s remaining four
conference channels. The test p uts the NPE in loop-around mode and instructs it
to talk on a specified time slot while listening to a 1004-Hz tone using the
Conference Channels. A GPTD then measures the signal and noise le vels of the
conferenced outpu t and reports whether or not these fall with in a specified
acceptabl e range.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane bo ard is inserted.
1. Check to ensure that the board translations are correct. Use the list config
command, and resolve any problems that are found.
2. If the board was found to be c orrectly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, check to ensure
that there is a valid board inserted.
Table 9-415. TEST #56 MFAT Electronic Power Feed Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page