Maintenance Object Repair Procedures
9-22ADX8D-PT (AUDIX Digital Port)
9
7 FAIL Conference Test failed on the primary channel. Some users may not notice
a disruption in service. In extreme cases, the conferencing feature may
not work at all.
14 FAIL The primary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
15 FAIL The control channel between the processor and DEFINITY AUDIX circuit
pack is not transmitting properly. User impact may range from no
noticeable effect to loss of use of this port. This failure could also be
disruptive to other users.
16 FAIL The secondary voic e channel is not transmitting properly. User imp act
may range from no noticeable effect to loss of use of this port.
None FAIL The test failed for reasons external to the DEFINITY AUDIX circuit pack.
1. Run circuit pack tests to check the Tone Generator circuit pack and
the Tone Detector circuit pack by using the test board UUCSS s
command.
2. Resolve any problems that are detected on the Tone Generator circuit
pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly, and if the test still fails, replace the DEFINITY AUDIX circuit
pack (see precaution at the beginning of this section).
PASS Voice and Control Channel Local Loop test passed. All channels are
transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this test up to
10 times and see if it continues to pass.
2. If complaints still exist, examine the connections.
Table 9-8. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code Test
Result Description/Recommendation