DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-645DS1-FAC (DS1 Facility)

9
Error Log Entries and Test to Clear Values
Notes:
When problems persist, resetting the DS1 CONV circuit pack via the reset board command may temporari ly resolve the error condition and restore ser vice until further assistance is provid ed.a. A major failure occurred on the DS1 interface hard ware on the DS1 CONV circuit pack assoc iated with this DS1 facility. Replace the DS1 CONV
circuit pack.
Table 9-255. DS1 Facility Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test ds1-facility UUCSSf
sh r 1
1(a) Failure Audit #949 MAJOR ON test board UUCSS sh r 1
18(b) 0 busyout ds1-fac ility
UUCSSf WARNING OFF release ds1-facility
UUCSS
257(c) Failure Audit #949 MINOR ON test b oard UUCSS sh r 1
513(d) 1 Failure Audit #949 MINOR OFF test board UUCSS sh r 1
513(d) 2 Failure Audit #949 MINOR OFF test board UUCSS sh r 1
856(e) DS1 Facility Query
for Slips/Misframes
#972
MINOR OFF none
1025(f) Failure Audit #949 MAJOR2
2. These failures are logged as a WARNING alarm when the error is first reported. The alarm severity
is raised to a MAJOR in 15 minutes if the problem persists.
OFF test board UUCSS sh r 1
1281(g) None Failure Audit #949 MAJOR2OFF test board UUCSS sh r 1
1281(g) 1 Failure Audit #949 MAJOR2OFF test board UUCSS sh r 1
1281(g) 2 Failure Audit #949 MAJOR2OFF test board UUCSS sh r 1
1537(h) Failure Audit #949 MAJOR2OFF test b oard UUCSS sh r 1
1793(i) Failure Audit #949 MAJOR2OFF test board UUCSS sh r 1
2065(j) DS1 Facility Query
for Slips/Misframes
#972
MINOR OFF none
2305(k) Failure Audit #949 MAJOR OFF test board UUCSS sh r 1
2561(l) Failure Audit #949 MINOR3
3. This failure is logged as a WARNING alarm when the error is first reported. The alarm severity is
raised to a MINOR in 15 minutes if the problem persists.
OFF test board UUCSS sh r 1