DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-270ATM-TRK (Circuit Emulation Service Circuit Pack)
9
Control Channel Loop Test (#52)
The non-destructive Control Channel Loop Test is part of the maintenanc e
subsystem’s Common Port Board Testing feature. The Common Port Board test
sends board vintag e queries to a port circ uit pack and c hecks the responses.
CCMS downlink notifications tell the circ uit pack which TDM Bus (A or B) car ries
the control channel and whic h carries the touch tones.
The test passes if the port circ uit pack responds. The test aborts if the circuit
pack does not resp ond. The test fails otherwise.
Table 9-120. TEST #50 Connection Audit Test
Error
Code Test
Result Description/ Recommendation
None
2100 ABORT System resources required for this test are not available.
1. Retry the command up to 5 times at 1-minute intervals.
1019 ABORT The test aborted because a test was already running on the port.
1. Retry the command up to 5 times at 1-minute intervals.
FAIL Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
PASS The circuit pack has been updated with its translation.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane bo ard is inserted.
1. Check the board translations.
2. If the ATM-TRK circuit pack is not administered, run add atm trunk
UUCSS.
3. If the ATM-TRK circuit pack is administered correctly, check the error log.
4. If ATM-TRK circuit pack is hyperactive, shut down, and reseat the circuit
pack to force re-initialization.
5. If the ATM-TRK circuit pack is correctly inserted, run busyout board.
6. Run reset board.
7. Run release busy board.
8. Run test board long to re-establish the linkage between the internal ID
and the port.
Continued on next page