DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-127ASAI-EPT

9
Error Log Entries and Test to Clear Values
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol. Timers associated with certain Layer 3 messages have expired before a required response was received . In the following table, the aux d ata column indicates whic h timer has just expired. For more information, refer to the Lucent ISDN-BRI Specification.
Table 9-50. ASAI-EPT Error Log Entries
Error
Type Aux
Data Associated Test Alarm Level
ASAI-EPT On/ Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test ASAI-ADJ
2 (a) 2-102 None
257 (b) Any BRI Layer 3
Query MAJ/WNG2
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
OFF test station ext r 2
test data-module ext r 2
351 (c) 0 none WARNING OFF busyout and release
station
513 (d) 0 None
769 (e) 0 None MAJOR OFF
2561 (f) 0 None
2562-
2566 (g) 0None
2567 (h) 0 None
2568 (i) 0 None
3329 (j) Any Signaling Link
Status (626) MAJ/WNGOFF
3584-
3839 (k) Any N one
3841 (l)
4095 Any None