DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Alarms, Errors, and Troubleshooting
5-2DEFINITY AUDIX System Power Procedures
5
Before powering down a c abinet or carrier that contains DEFINITY AUDIX
circuit packs (TN566), first p ower down the AUDIX unit to avoid damag ing
the AUDIX software. Instructions for powering d own this unit are in the
‘‘DEFINITY AUDIX System Power Procedures’’ below, on the circ uit pack,
and in DEFINITY AUDIX documentation.
When you are finished working on a cab inet, replace and sec ure all panels
and covers to avoid d isseminating electromag netic interference.
DEFINITY AUDIX System Power Procedures

Manually Power Down AUDIX System

A yellow caution sticker on the syst em’s power unit notifies technic ians to shut
down the DEFINITY AUDIX System prior to powering down the system.
1. Using a pointed ob ject, such as a pap er clip or pen (d o not use a pencil),
press the Boot/shutdown button. The butto n is located at the top rig ht
portion of the front panel.
2. Hold the boot/Shutdown button i n until the LCD display flashes the
message MSHUT.
3. Release the Boot/Shutdown button.
NOTE:
The DEFINITY AUDIX System takes about five minutes to shut down.
The “heartbeat” ind ication on the display c ontinues to flash.

Manually Power Up AUDIX System

1. Using a pointed ob ject such as a pap er clip or a pen (d o not use a pencil),
press the Boot/Shutdown button.
2. Hold the boot/Shutdown button in un til the display indic ates the message,
BTEST, steady on.
3. Release the Boot/Shutdown button. the DEFINITY AUDIX system takes
approximately 5 minutes to power up .
The display has the following seq uence of steady on messag es:
—OSINIT
—OS
—AINIT
—ADX