DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-314BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)]

9
performed on b oth B-channels (B1 and B2) assoc iated with a BRI port. If this test fails on either channel, any endp oints connected to the port are taken out-of-service.This test is not executed for ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT because the B-channels associated with the port are not used by ASAI or Lucent adjuncts
Table 9-139. TEST #617 NPE Crosstalk Test
Error
Code Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port PCSSpp command to determine the station
extension or trunk group/m e mber number of the p ort. Use the status
bri-port PCSSpp command to determine the service state of the port. If
the service state indicates that the port is in use, then the port is
unavailable for certain tests. (Refer to the ‘‘Status Commands’’ section in
Chapter 8, ‘‘Maintenance Commands’’, for a full description of all
possible states.) Wait until the port is idle before retesting.
2. If the port status is idle, then retry the command at one-minute intervals
a maximum of five times.
3. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a user for a valid call.
1. Use the status station command for the station associated with this
port and determine when the port is available for testing.
2. Retry the command at one-minute intervals a maximum of five times.
3. If the test continues to abort and the port is not in use, escalate the
problem.
1005 ABORT This test is not valid for this type of translation. Ports administered as “ASAI”
or “ADJK” can not run this test, because the B channels associated with the
port are not used by ASAI or Lucent Adjunct Links. This is a normal
condition.
2012 ABORT Internal System Error.
2100 ABORT Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1
2FAIL The NPE of the tested port was found to be transmitting in error. This causes
noisy and unreliable connections. Error code 1 indicates that the NPE
Crosstalk Test failed on Channel B1. Error code 2 indicates that the NPE
Crosstalk Test failed on Channel B1.
1. Replace the circuit pack.