DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-75ANL-24-L (24-Port Analog Line)
9
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL The reflective loop around test failed. This could cause noisy or unreliable
connections, or users calling this port may hear an echo. The problem can
also be off-board.
1. Since the test may be affec ted by a line seizure, repeat the test at
1-minute intervals for a maximum of 5 times.
2. Run circuit pack tests to check the tone generator circuit pac k and the
tone detector circuit pack b y using the test board UUCSS short
command.
3. Resolve any problems on the tone generator circuit pack or the tone
detector circuit pack.
4. If the tone generator and tone detector circuit packs are functioning
properly and the test still fails and a voice terminal is connected and
wired properly, replace the analog line circuit pack.
PASS The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investig ated by
using other port tests, by examining station wiring, or by examining the
station. Refer to ‘‘LA85 Port Tester’’ in Chapter 5 for instructions on using the
port tester.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect b oard is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command and resolve an y problems.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-estab li sh the
linkage between the internal ID and the port. If this is not the case,
check to ensure that there is a valid board inserted.
Table 9-32. TEST #161 Looparound Test — Continued
Error
Code Test
Result Description/Recommendation
Continued on next page