DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1286PMS-LINK (Property Management System Link)
9
m. The link was taken down by the switch b ecause the threshold for
application p rotocol violations has been exceed ed by the PMS. The
protocol never started and messages were received and /or messages
were received in a state in which they were not expected. (Refer to Error
Type 2817 for recommended strategy.)
n. Link was taken down by the switch b ecause the threshold for link p rotocol
violations has been exceed ed by the PMS. PMS is sending ‘‘garbage’’ to
the switch.
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the table below. By c learing
error codes associated with the
Link Retry Test
, for example, you may also clear
errors generated from other tests in the testin g sequence.
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external PMS
device. If the link has been disconnected alread y, then this test just returns
‘‘PASS.’’ All resources allocated for a PMS Link are released after this test .
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
Link Tear Down Test (#213) X D
Link Retry Test (#215) X X ND