Table 9-499. TEST #885 Private Looparound Tests
Error
Code Test
Result Description/ Recommendation
1006
1137 ABORT Packet Interface circ uit pack is in the out-of-serv ice state so normal
maintenance tests will not run on that circuit pack.
1. Request a Packet Interface circuit pack reset using the reset
packet-interface CS command. Refer to the Packet Interface Reset Test
(#889) repair procedures for further action.
1334 ABORT The Packet Interface circuit pack c ommand queue is full. This should be a
temporary condition caused by a high rate of command s being sent to a
Packet Interface circuit pack. Continued operation with a full command q ueue
will cause a system WARM restart that may escalate to more severe restart
levels.
1. Retry the command at 10-second intervals, a maximum of 5 times.
1338 ABORT The test is not allowed to run since a planned SPE interchange is in progress.
A planned interchange may be caused b y 24 hour scheduled testing. During
this time the terminal will be held out of service but it should recover
automatically after 3 minutes.
1. Wait 3 minutes and retry the command.
1339 ABORT The test could not run on the standby Packet Interface circuit p ack because
the standby SPE is unavailable.
1. Refer to the STBY-S P E maintenance documentation for information on why
a standby SPE may be unavailable and what repair actions should be
taken. The status spe screen should indicate that handshake is down.
This may be caused by a variety of reasons such as the setting the
SPE-SELECT switches on the DUPINT circuit packs to the position of the
active SPE, a failure of the DUPINT circuit pack, or loss of power on the
standby SPE, The
SPE Select ed fie ld
on the status spe screen will display
spe a
or
spe b
if the SPE-SELECT switches are in the a or b position,
respectively.
1347 ABORT The test could not run because refresh of the standby SPE’s memory is not
complete.
1. Enter status spe and verify that refresh is not complete. Wait until the
status screen indicates that refresh is complete and try the command
again. The status screen should indicate that shadowing is on. If some
event such as a major alarm on a Packet Interface circuit pack on the
stand by SPE cau ses sha dowing to turn off, ref resh ca nnot co mplet e and
abort code 1350 will be returned when the test packet-interface c ommand
is entered.