DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1910VC-BD
9
Notes:
a. The circuit pack stop ped functioning or it was removed from the system.
This alarm is logged ap proximately 11-minutes after the circuit p ack is
removed and/or the SAKI Sanity Test (#53) fails.
To resolve this error, insert a circuit pack in the same slot as the er ror
indicates, if the circ uit pack is not already in the sys tem. Or, if the circuit
pack is in the system and the red LED is on, then follow instructions for
Red alarms.
!CAUTION:
If the TN788 Voice Conditioner Circuit Pack (VC-BD) is not Vintage 2 or later, it must be replaced .
b. This circuit pack is b usied out by the busyout board UUCSS c ommand.
c. Transient communication problems exist b etween the switch and this
circuit pack. Execute the test board UUCSS command and refer to the
repair procedures for the Con trol Channel Looparound Test (#52).
d. The circuit pack detected an on-board hardware failure. The reported aux
data values correspond to the following detected errors:
1025 (f) 4363 NPE Audit Test (#50)
1281 (g) Any SAKI Sanity Test (#53) MAJ On
1293 to
1294 (h) 46088
to
46096
SAKI Sanity Test (#53) MIN ON
1538 (i) 46082 MIN ON
1. Run the short test sequence first. If all tests pass, run the long test sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
Error Description
4352 External RAM error
4353 Internal RAM error
4355 ROM Checksum error
4357 Instruc tion set error
Table 9-705. VC-BD Error Log Entries — Continued
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
Continued on next page