DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1933WAE-PORT (Wideband Access Endpoint Port)

9
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the se lected time slot, and does not cross over to t ime slots reserved for other connec tions. If the NPE is not working correctly, one-way and noisy connec tions may be observed. This test is usually part of a port’s long test seque nce and takes 20 to 30 seconds to comp lete
Table 9-716. TEST #6 NPE Crosstalk Test
Error
Code Test
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be in
use on a valid call. Use the status access-endpoint extension or command to
determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1001 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Use status health to determine if the system is experiencing
heavy traffic.
1. If system has no TDM-BUS errors and is not handling heavy traffic, retry
the command at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
too big for the numb er of Tone Detectors present, or some Tone Detectors may
be out of service. List measurement tone-receiver disp lays information on
the system’s tone receivers.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port has been seized by a us er for a valid call. Use status
access-endpoint extension to determine when the port is available for testing.
The port is available when it i s in the in-service/idle state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1020 ABORT The test did not run because of a previously existing error on the specific p ort
or a more general circ uit pack error.
1. Examine the Error Log for exist ing errors against this p ort or the circui t
pack and attempt to diagnose the already existing error.
Continued on next page