DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-284status link (with PGATE)
8

Field descriptions, page 3

NOTE:

A dash (-) or a colon (:) b etween numbers indicates a ll numbers including

and between the indic ated numbers.

status link (with PGATE)

(r model with PGATE circuit pack)

Output

The following example shows the output from the st atus link 1 command.

UP: Channels are up.
DN: Channels are down.
PND: Channels are in a pending state from the down to the up state (processor
channels only)
Action/ Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
status link
n
Number of the administered
link.
Example:
status link 1
init
inads
craft
none none
status link 1 Page 3 of 3
PROCESSOR CHANNEL STATUS
UP: 001, 007, 010-115
199, 300:310
DN: 001-002
PND: 003, 216-220, 299