Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1DS1 Interface circuit pack d etects a hardware error on the
DS1 DID trunk. The Aux Data field indicates the following :
DID-DS1 Trunk Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test trunk
grp#/mbr#
1(a) Any
15(b) Any Port Audit and
Update Test (#36)
18(c) WARNING OFF release trunk
grp#/mbr#
130(d) None WARNING ON test trunk
grp#/mbr#
257(e) 57474
57473
513(f) 57392 MIN/MAJ2
2. This alarm will only be raised when the System-Parameter Country form has the Base T one Generato r
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group
are out of service, then the alarm w ill be upgraded to a MAJOR alarm.
769(g) 57393 MIN/MAJ2
1281 Conference Circuit
Test (#7) MIN/
WRN3
3. Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
ON test trunk
grp#/mbr#
l r 4
1537 NPE Crosstalk
Test (#6) MIN/
WRN3ON test trunk
grp#/mbr#
l r 3
1793(h) test board
UUCSS
l
2305(i) 50944 None MIN/MAJ 2OFF
3840(j) Port Audit and
Update Test (#36)
57476 On-hook before wink
57477 On-hook before read y to receive digits
57485 Wink too short for valid sig nal