DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1634TAPE

9
The "service state" field in the Alarm Log refers to the acc essibility of the device . IN (in service) means that users can ac cess the device a nd all maintenance tests will run. MTC (maintenance busy) means that the d evice is "busied out" and users cannot access it alth ough all demand maintenanc e tests will run. OUT (out
1025 (i) any Tape Write-Read
(#810) MINOR OFF test tape a|b2 long rep 2
1281 (j) any Tape Diagnostics
(#813) MINOR ON test tape a|b2 sh rep 2
1537 (k) any Tape Write-Read
(#810) WARNING OFF test tape a|b2 long rep 2
1793 (l) any Tape Looparound
(#814) MINOR OFF test tape a|b2 sh rep 2
2049 (m) any Tape Looparound
(#814) MINOR OFF test tape a|b2 sh rep 2
2305 (n) 2Tape Frmwr Counters
(#812) WARNING OFF reset tape a|b2
2306 (o) 5504 Tape Frmwr Counters
(#812) WARNING OFF test tape a|b2 sh rep 2
2561 (p) any Tape Write-Read
(#810) MINOR OFF test tape a|b2 long rep 2
2817 (q) any Tape Status (#815) WARNING ON test tape a|b2 sh rep 2
3073 (r) any In-line MINOR ON test tape a|b2 long rep 2
3329 (s) any Tape Audit (#811) MINOR OFF test tape a|b2 long rep 2
3585 (t) 408 MAJOR/
MINOR OFF
3585 (u) 409 MAJOR/
MINOR OFF
3841 (v) 3Miscellaneous MINOR OFF test tap e a|b* long rep 1
1. The number of times the tape has been accessed. This number is at least 90% of the manufacturer’s
recommended limit.
2. In a system with a simplex SPE, the carrier does not have to be specified. In a system with duplicated
SPE, the carrier (a or b) must be specified.
3. If error type 1 with aux data of 123 is present, this field will have the out of service cause data. See the

MSS Error Actions

table at the end of the section on TAPE.
Table 9-616. TAPE Error Log Entries — Continued
Error
Type Aux
Data1Associated Test Alarm
Level On/Off
Board Test to Clear Value
Continued on next page