DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1802TONE-PT (Tone Generator)

9
3. If the problem persists, rep lace the Tone-Clock circuit pack by following the steps outlined in the ‘‘How to Replac e the Tone-Clock Circuit Pack’’ section
Table 9-672. TEST #40 Tone Generator Transmission Test
Error
Code Test
Result Description/ Recommendation
None ABORT The system was not able to allocate all the resources needed for this test or
there was an Internal system error.
1 ABORT The system could not allocate all the resources needed to test the DTMF
tones.
1001 ABORT The system was not able to put the tone generation facility in the
appropriate mode to test it.
1002 ABORT The system could not allocate time slots for the test connection. This can
happen when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM Bus via the test tdm port-network PN#
command.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test connection. This
can happen when the system is heavily loaded or there is not a Tone
Detector circuit pack in the port network where this test is being executed .
1. Make sure there is a Tone Detector circuit pack in the same port
network.
2. If a Tone Detector circuit pack is missing, install one in the same port
network.
3. Allow approximately 1-minute for Tone Detector maintenance to run on
the newly inserted Tone Detector circuit pack.
4. Retry the command at 1-minute intervals a maximum of 5 times.
1022 ABORT [G3r V2] Tone detection for the system is administered as wide broadband
(tone detection mode 5), and the Tone Detector used for this test was not a
TN420C. (the only circuit packs with this capability). GPTD ports on other
types of Tone Detector circuit packs are taken out of service since they
cannot provide the administered function.
1. Change the tone-detection mode administered on the
system-parameters country-options form (see

DEFINITY

Communications System Generic 3 V2 Implementation,

555-230-653,
Or
2. Remove all non-TN420C circuit packs from the system.
2000 ABORT Response to the test request was not received within the allowable time
period. System resources required for this test are not av ailable.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page