DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-78ANL-LINE, ANL-NE-L (8-Port Analog Line)
9
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. These are in-line errors that can only be resolved over time.
Aux Data 40960 Indicates that too many si multaneous incoming ringing
attempts were made on this board . Only 4 ports on a board may ring
simultaneously. A 5th incoming call will c ause an inline error from the
board.
Aux Data 40975 indicates that the terminal equipment was on-hook when
ring-tip was detec ted during ringing. This usually indicates a failure in the
terminal equipment or the typ e of terminal has a low ringer impedanc e.
Call the terminal equipment and verify that the terminal rings. If the
terminal doesn’t ring, then rep lace it. Otherwise, issue the test port
UUCSSpp command, and follow the p rocedure for Test #48.
8-Port Analog Line Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test
description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) 40960
40977
40975
None
15 (b) Any Audits and Updates Test
(#36)
18 0 busy-out station
extension
WARNING OFF release station
extension
130 (c) None WARNING ON test port UUCSSpp sh
257 (d) Station Present Test
(#48) WARNING OFF test port UUCSSpp sh r 3
513 Battery Feed Test (#35) MIN/WRN2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
ON test port UUCSSpp sh r 2
769 (e) Loop Around and
Conference Test (#47) test port UUCSSpp l r 3
1025 NPE Crosstalk Test (#6) MIN/WRN2ON test port UUCSSpp l r 3
1281 (f)
1793 (f)