DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-7Contention Between Simultaneous Commands
8
Contention Between Simultaneous Commands
The following limits apply to simultaneous m aintenance and administrati on
activities:
â– Up to 8 users can be log ged into the system at the same time.
â– Up to 5 maintenance comman ds can run conc urrently.
Result One of the following results:
PASS: The command successfully completed . For a test command
this indicates that no errors were d etected by the test.
ABORT: The command was prevented from com pleting. See Error
Code below.
FAIL: Indicates that a serious error was detected by the test. See Error
Code below.
NO BOARD: The system does not detect a circ uit pack in the loc ation
specified on the c ommand line.
CONFLICT: Another user was testing this maintenance objec t.
EPN-DOWN: The EPN holding the MO is inacc essible. The Expansion
Archangel Link may be d own.
DISABLED: The MO or test has been disabled b y the Tier 3 disable
command.
NOT ASSIGNED: The location specified does not have a circ uit pack
administered to it.
EXTRA BOARD: This result can appear for the Maintenanc e/Test, Call
Classifier, Tone Detector, Announcement, and Speech Synthesis
circuit pac ks. Each of these circuit p acks has restrictions on how many
can be in the system or a port network:
Maintenance/Test circuit pac k: 1 per port network
Tone Detector circuit pac k: up to 50 per system
Call Classifier circuit pac k: up to 25 per system
Speech Synthesis circuit p ack: 40 per system
Announcement circuit p ack: 1 per system
Remove the extra circuit pac k(s).
Error
Code A number indicating the reason for a FAIL or ABORT result. For test
commands and other c ommands that return a test result, c onsult the
tables of test error codes und er the relevant MO. For busyout, release
and reset commands, see ‘‘Common Abort and Fail Codes’’ and Test
Commands.