DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1932WAE-PORT (Wideband Access Endpoint Port)
9
Notes:
a. The wideband acc ess endpoint has been b usied out by a busyout
access-endpoint extension command. No c alls can be made to this
extension.
b. The circuit pack has been removed or has been insane f or more than
11-minutes. To clear the error, reinsert or replace the circ uit pack.
c. The Conference Circuit Test (#7) failed on this port. See Test #7 for repair
procedures.
d. The NPE Crosstalk Test (#6) failed on this port. See Test #6 for repair
procedures.
e. The TN464C UDS1 Interface circuit pack has failed. See UDS1-BD.
f. The Port Audit and Update Test (#36) failed due to an internal syste m
error. Enter status access-endpoint extension and verify the status of the
port. I f the wideband access e ndpoint port is out of serv ice, en ter release
access-endpoint extension to put it bac k into service. Retry the test
command.
Technician-Demand T e sts: Descri ptions and Err or
Codes
Always investigate tests in the order p resented in the table below whe n
inspecting errors in the sy stem. By clearing error cod es associated with the
NPE
Crosstalk Test
, for example, you may also clear errors g enerated from other tests
in the testing sequenc e.
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
NPE Crosstalk Test (#6) X ND
Conference Circuit Test (#7) X ND
Port Audit and Update Test (#36) X X ND