9-1699TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
9
Table 9-639. TEST #258 ISDN TEST Call
Error
Code Test
Result Description/ Recommendation
4 ABORT There is a problem with the Processor Interface Link.
1. Refer to the PI-LINK (Processor Interface Link) Maintenance
documentation.
1004 ABORT B channel in use.
1. Determine if a call is active on this ISDN Trunk-side BRI trunk via the
status trunk command.
2. When the service state indicates in-service/idle, retry the test.
1005 ABORT Bad Configuration (that is, no Maintenance/Test circuit pack)
Issue the test trunk <trunk Group/trunk member> command and make
sure there is a DATA-CHL (NETCON channel) administered.
1018 ABORT Test call is disabled.
1. Enable Maintenance on the Trunk Group form.
1024 ABORT (M/T-DIG) Maintenance/Test Digital Port in use.
1. Wait until yellow and green LEDs are turned off on the M/T-BD
(Maintenance/Test circuit pack).
2. Retry the test. If problem persists, refer to M/T-DIG (Maintenance/Test
Digital Port) documentation.
1113 ABORT The signaling link has failed; the system cannot send any messages on
behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State Check Test).
1114 ABORT The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1116 ABORT The switch could not appropriately change the ISDN service state.
1. Determine if a call is active on this ISDN Trunk-side BRI trunk (use the
status trunk command).
2. If not, check the Error and Alarm Logs for problems with this TBRI-TRK
MO.
1117 ABORT ISDN B-channel maintenance message is already outstanding.
1. Wait two minutes, then try again.
1118 ABORT Far-end of ISDN trunk is not administered.
1. Check the administration of the far-end ISDN trunk.
2. Issue the status trunk command and try the test again.
Continued on next page