DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-124ASAI-BD (Multi-Application Platform Board)
9
ASAI-BD (Multi-Application Platform Board)
Maintenance testing of the c ommon circuit pac k is handled by on-b oard firmware
and SPE- cont rolle d tes ts. Ma inten anc e soft ware q ueri es the firm ware fo r erro r
and alarm information, status, and test results. Firmware automatically reports
error c ond itio ns tha t resu lt in SPE- cont rolle d tes ting .
For MAPD board insertion, the switch makes an ad ditional board q uery if any of
the following circuit p acks are inserted:
For any of the above initial board up links, the switch queries the b oard for
administration data as well as rep orting the switch software release and the
system type.
For the native mode, the response to the board query downlink messag es
consists of several CCMS uplink messages tha t identify the true board c ode,
vintage, suffix, emulation type, and number of reserved slots need ed.
NOTE:
See also ASAI-PT/ASAI-EPT (BRI Line) maintenance documentation for
related line information. See the following exc eptions listed below:
Hyperactivity: currently, the common c ircuit pack is c onsidered
"hyperactive" if the Service Dispatcher rece ives 200 uplink
messages from the circuit p ack in a 10-second p eriod. Since
MAPD has 32 ports, the hyperacti vity limit increases to 500 uplink
MO Name (in
Alarm Log) Alarm
Level Initial Command to Run 1
1. Where UU is the universal cabinet number (1 for PPN and 2-44 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ..., and so forth); and p p is the
two digit port number (01, 02, 03, ...).
Full Name of MO
ASAI-BD MIN test board UUCSS pp ASAI-BD
ASAI-BD WRN test board UUCSS pp ASAI-BD
Circuit Pack Vintage
TN754 49
TN556 49 ,
80 or greater
TN800 an y