DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1775TIE-TRK (Analog Tie Trunk)
9
2053 ABORT The test call could not be established, but no information on why is available.
1. Retry the command at 1-minute intervals for a maximum of 5 retries.
2056 ABORT An error occurred while trying to obtain results from the TN771 circuit pack.
1. Test the TN771 circuit packs.
FAIL Measured transmission performance was in the unacceptable range as
administered on the trunk group form. Retrieve a measurement report via the list
testcalls command. Make sure that ATMS thresho lds are set properly on page 4
of the trunk group form. Besides the facility, test failures can be caused by faulty
test lines or switch paths. If the measurements point to a facility problem, report
the results to the trunk vendor.
8000 FAIL Measured transmission performance was in the marginal range as administered
on the trunk group form. This generally means that the trunk is usable but has an
undesirable amount of noise or loss. If the user does not report unacceptable
effects, it may not be necessary to take any action. Retrieve a measurement
report via the list testcalls command. Make sure that ATMS thresholds are set
properly on pag e 4 of the trunk group form.
Table 9-665. TEST #844-848 Transmission Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page