DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-363test tape
8
Output
The following display shows a typical result when test sys-link 1e0201 current is
entered.
test tape
test tape [C] [short | long] [repeat # | clear] [schedule]
The test tape command performs a series of tests on the tap e circuit pac k and
tape cartridg e. The standard cartrid ge used for bac kups of the disk is
compatible with this test. The tape c artridge is rewound and a specific p ortion of
the tape is used for test reads a nd writes. Tapes used for core dumps have an
incompatible file system and should not be used for this test.
The cabinet is always 1 and need not be entered. Carrier a or b must be
specified only for systems with duplicated SPEs.
This command aborts if any other MSS operation has a lready begun.
Failure of the tape test may result in the tape being placed in an out -of-service
state. In this state, access to the ta pe by all system software exc ept maintenance
is blocked.
When the host-adapter is taken out of servic e due to failures of its tests, or fails a
reset and becomes uninstalled , the tape is also plac ed in the uninstalled state
test sys-link 1e0201 current Page 1 SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01E0201 SYS-LINK LNL 985 PASS
01A1 PKT-INT 886 PASS
01A1 PKT-INT 887 PASS
PN 01 PKT-BUS 572 PASS
PN 01 PKT-BUS 573 PASS
01E01 EXP-INTF 237 PASS
01E01 EXP-INTF 238 PASS
01E01 EXP-INTF 240 PASS
01E01 EXP-INTF 241 PASS
01E01 EXP-INTF 589 PASS
01E01 EXP-INTF 316 PASS
1 A-PNC FIBER-LK 777 PASS
1 A-PNC FIBER-LK 759 PASS
1 A-PNC FIBER-LK 237 PASS
1 A-PNC FIBER-LK 238 PASS
press CANCEL to quit -- press NEXT PAGE to continue