DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-237ATM-SGRP (ATM Signaling Group)
9
b. Check out other errors against ATM-SGRP, ATM-TRK, and other
hardware components on the link.
There is no test to clear these errors. The error counter is decremented by
1 every 15 minutes.
b. Error Type 18: the ATM circuit pack has been busied out (eith er busyout
atm sig-grp or busyout board UUCSS).
1. Release the ATM signaling group (release atm sig-grp) or the
circuit pack (release board UUCSS).
c. Error Type 257: the primary signaling channel c onnection has been lost for
more than 90 seconds.
The associated B-channels are p laced in the ISDN
Maintenance/Far-End state.
The B-channels are not usable for outgoing calls, although
incoming calls can be accepted.
The switch automatically attempts to recover the signaling link.
1. Pay particular attention to the results of Test #636 (Primary
Signaling Link Hardware Check) in the te st sequence.
When the link does recover, the B-channels are negoti ated back to
the In-Service state and their alarms are retired.
2. When this error occurs, the state of the Signaling Group is changed
to out-of-service (verify using the status sig-group c ommand).
d. Error Type 769: signaling link hardware error.
Service-affecting failures of the hardware used to transport the D-Channel
are reported to the ATM CES Signaling Group MO. Maintenance logs th is
error, places the D-Channel into the OOS state, and raises a board-level
alarm. The D-Channel is returned to service and the alarm is retired once
the hardware failure condition c lears.
e. Error Type 1281: Degraded PVC Alarms indicate that a partic ular
Permanent Virtual Circuit, or signaling group , has encountered sufficient
errors to exceed firmware thresholds. Op erations can continue b ut at a
lower level of reliability or perfor mance. Firmware filters these alarms so
that only one is reported active at a g iven time. The following in-line error is
considered a Degr aded PVC Alarm:
Excessive AAL - The AAL layer is experiencing an excessive
number of errors in trying to reconstruc t Service Data Unit (SDUs).
Possible causes:
Something may be wrong with the ATM switch.
The commu nication paths on the other side of the ATM
switch may be noisy.
The sendi ng node might not be healthy.
Could be a problem with c ongestion on the ATM switch.