DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1754TIE-DS1 (DS1 Tie Trunk)
9
FAIL The far-end trunk did not respond to the seizure of the near-end trunk within
the allowable time period. This test could have associated in-line errors in
the error log.
1. Enter the list configuration board UUCSS command. If the circuit
pack is a TN767B vintage 8 or 9, a failure of test 136 causes a
subsequent failure of test 7 due to a firmware bug. Eventually, the board
and all of its ports will be taken out of service and extraneous on-board
alarms will be generated. Replace the circuit p ack with a TN767C V3 or
later.
2. Verify that the ’Trunk Type’ field on the ’Trunk Administration’ screen
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log. If
present, refer to the DS1-BD (DS1 trunk circuit pack) Maintenance
documentation or to the UDS1-BD (UDS1 trunk circuit pack)
Maintenance documentation.
4. Retry the test at 1-minute intervals for a maximum of 5 times.
2000 FAIL Response to the seizure message was not received within the allowable
time period.
1. Enter the list configuration board UUCSS command. If the circuit
pack is a TN767B vintage 8 or 9, a failure of test 136 causes a
subsequent failure of test 7 due to a firmware bug. Eventually, the board
and all of its ports will be taken out of service and extraneous on-board
alarms will be generated. Replace the circuit p ack with a TN767C V3 or
later.
2. Verify that the ’Trunk Type’ field on the ’Trunk Administration’ screen
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log. If
present, refer to the DS1-BD (DS1 trunk circuit pack) Maintenance
documentation or to the UDS1-BD (UDS1 trunk circuit pack)
Maintenance documentation.
4. Retry the test at 1-minute intervals for a maximum of 5 times.
PASS The trunk can be seized for an outgoing call.
Table 9-656. TEST #136 DS1 Tie Trunk Seizure Test — Continued
Error
Code Test Result Description/ Recommendation
Continued on next page