Table 9-176. TEST #7 Conference Circuit Test
Error
Code Test
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT The test was aborted. System resources required to run this test were not
available. The port may be busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use the statu s trunk command to
determine the service s tate of the port. If the port is i n use, wait until the
port is idle before testing.
2. If the port status is active but the port is not in use (no calls), check the
error log for error type 1025 (see the error log table for a description of
this error and required actions). The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out of service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic
and the port status is id le, retry the command at 1-m inute intervals for a
maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some of the tone
detectors may be out of service. Issue the list measurements
tone-receiver command to displ ay basic information ab out the system’s
tone receivers.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT err o rs.
3. If neither condition exists, retry the command at 1-minute intervals for a
maximum of 5 times.
1004 ABORT The port has been seized by a user for a valid call.
1. Use the status station or status trunk command to determine when
the port is available for testing.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
1018 ABORT The test was disabled via translation. You may want to determine why the
test has been disabled before you enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk Administration’
screen is set to 'n.’ To enable the test, change the trunk administration
and enter 'y' into the 'Maintenance Test' field.
2. Repeat the test.