DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-953ISDN-SGR (ISDN-PRI Signaling Group)

9
and generate an associated Warning alarm independen t of the hardware configuration used for the D-channels.
Table 9-365. TEST #647 Layer 2 Status Query Test
Error
Code Test
Result Description/ Recommendation
1132 ABORT Internal system error:
The port location for the p rimary ISDN-PRI D-channel is not known. This
condition should not be possible since an administered DS1 circ uit pack must
be specified when a Signaling Group is administered:
1. Retry the command at one minute intervals a maximum of five times.
1134 ABORT Internal system error:
The associated DS1 circuit pack is not administered. This condition should not
be possible sinc e an administered DS1 circ uit pack must be spe cified when a
Signaling Group is ad ministered.
1. Retry the command at one minute intervals a maximum of three times.
2500 ABORT Internal system error:
1. Retry the command at one minute intervals a maximum of five times.
1 FAIL Layer 2 of the primary signaling channel is down:
1. Examine the results of the Primary Signaling Test (#636) and follow
recommendations provided there.
2. If test #636 passes, the Layer 2 Query test may still fail if the Signaling
Channel at the far end has not been administered correctly or if the
Signaling Channel has been busied out. Verify that the Primary Signaling
Channel (D-channel) at the far end has been administered correctly. Verify
that the DS1 port used for the Primary D-channel has not been busied out at
the far end.
2 FAIL Layer 2 of the secondary signaling channel is down.
1. Examine the results of Secondary Signaling Link Hardware Test (#639) and
follow recommendations provided there.
2. If tests #639 passes, the Layer 2 Query test may still fail if the Signaling
Channel at the far end has not been administered correctly or if the
Signaling Channel has been busied out. Verify that the Secondary Signaling
Channel (D-channel) at the far end has been administered correctly. Verify
that the DS1 port used for the Secondary D-channel has not been busied
out at the far end.
Continued on next page