DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1229PGATE-PT (Packet Gateway Port)

9
far-end and the link had b een up. If this occurs, exec ute the test port UUCSSpp long command and cons ult the repair procedures b eginning at Packet Gateway Switched Port Loop-Around Test #599.
Table 9-490. TEST #613 Level 1 State Inquiry Test
Error
Code Test
Result Description/ Recommendation
2000 ABORT Response to the test was not received from the Packet Gateway circuit pack
X.25 port within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the other
ports on the board are not in use (Yellow LED is off). Reset the circuit p ack
by performing the busyout board UUCSS and the reset board UUCSS
commands.
2. If this result occurs again, replace the circuit p ack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2100 ABORT The necessary system resources to execute the test could not be allocated.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 FAIL The Clear To Send lead is ‘‘low’’ indicating a problem with the data set or the
cable attached to the port.
1. Repeat the test.
2. If the test still fails, verify that the data set and the Packet Gateway port are
properly attached to the cable and the data set is powered on.
3. Place the data set in the ‘‘Local Loopback’’ mode. Consult the repair
procedures for the Packet Gateway Port Remote Loop-Around test (#611).
2 FAIL The Data Carrier Detect lead is ‘‘low’’ indicating a problem on the transmission
side of the data set.
1. Repeat the test.
2. If the test still fails, verify the integrity of the wiring on the transmission side
of the data set. Make sure that the data set is properly attached to the
transmission line.
3. If the local transmission wiring is intact, notify the authority responsible for
resolving off-premise transmission facility problems. The Packet Gateway
Port Remote Loop-Around Test (#611) may be useful in diagnosing this
problem.
PASS The Level 1 interface is healthy, both the DCD and CTS leads in the RS423
cable or TDM bus are ‘‘high.’’
Continued on next page