DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1110M/T-DIG (Maintenance/Test Digital Port)
9
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. This error indicates a hardware failure on the Digital Port c ircuitry. Replace
the Maintenance/Test circuit pack if the alar m is not resolved by the
command above.
b. The port has been bus ied out via the busy-out port UUCSSpp command.
c. This error indicates that Maintenanc e/Test Digital Port is talking on more
than just its assigned time slot. Replac e the Maintenance/Test circuit pack.
d. This error indicates that the Maintenance /Test Digital Port has failed its
self-test. Since the Digital Port Sanity Test runs only on port 2, but tests
both ports 2 and 3, b oth ports will be alarmed when the test fails . Note that
the command above ind icates to test port 2, even if the error is logg ed
against port 3.
e. This error indicates that the Maintenance/Test Digital Port has been unable
to successfully loop d ata from a tone generator to a tone detector.
f. This error indicated that call p rocessing records did not agree with
on-board records for the hook state (on-/off-hoo k) of the Maintenance/Test
Digital Port. This error is not service-affecting a nd no action is required.
M/T-DIG Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test S e quence first. If all tests pass, run the Long Te st Sequence. Refer to the appropriate
test description and follow the recommended proc edures.
0 Any Any Any test port UUCSSpp
1 (a) 41018 none MINOR ON test port UUCSSpp l r 3
18 (b) 0 busy-out port UUCSSpp WARNING OFF release port UUCSSpp
257 (c) Any NPE Crosstalk Test (#9) MINOR ON test p ort UUCSSpp l r 3
513 (d) Any Digital Port Sanity Test
(#565) MINOR ON test port
UUCSS
02 r 2
769 (e) Any Digital Port Loop Around
Test (#13) MINOR ON test port UUCSSpp r 3
3840 (f) Any Hook State Inquiry test
(#566)