DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-128list configuration
8
■ds1—Specifies the display o f all the DS1 (TN722, TN767 and TN464)
circuit packs administered and/or p hysically inserted in port carriers on
the entire system.
■port-network pn#—Specifies the display of all circuit packs located in a
specified p ort network. List cabinet gives the por t network number(s)
associated with a partic ular cabinet. Circuit p acks on switch nod e carriers
are not displayed when the p ort-network qualifier is entered. To display SN
circuit packs, use the all, carrier or board qualifiers.
■stations—Specifies the display of all circuit pac ks that can be assig ned
stations (including DS1 c ircuit packs for remote statio ns). All assigned
ports are displayed.
■trunks—Specifies the display of al l circuit pack s that can be used for
administering trunks. All assig ned ports are d isplayed.
Examples
list configuration carrier 2c schedule
list configuration port-network 5
list configuration stations print
Output
Assigned Ports:
■Board Number—The functional name of the circuit p ack
■Code—The TN or UN code and suffix of the circui t packs are disp layed.
■Vintage 00000000-065535 KKKKKK—The vintage number of the c ircuit
pack.
■no board—The circuit pack is administered but not physically installed.
■conflict—The circuit pack ad ministered to the slot differs from the c ircuit
pack that is physic ally installed.
■no link—The T1 link is down to a DS1 circuit pack.
Field definitions:
■Signaling—This field is displayed on ly when ”list configur ation ds1”
option is selected. The c ontents of the field are the same as the signaling
mode administered for the d s1 circuit pac k (via add/chang e ds1
command) or ”none” if the circuit pac k is not administered.
■Name—This field is displayed only whe n “list configuration d s1” option is
selected. The contents of the field are the same as the name administered
for the ds1 circuit pac k (by the add/change ds1 command) or “blank” if
the circuit pac k is not administered.