DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-202set options
8
Help Messages
If the user presses HELP after entering set options, the following messag e is
displayed:
Entry is not required
Error Messages
If the command entered is in confli ct with another currently executing c ommand,
then a message is displayed showing the login id of the conflicting user and the
conflicting c ommand. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a c ommand a resource prob lem occurs that requires
the user to restart the command, then the follo wing message is disp layed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resourc es are currently in use, then the
following message is displayed:
All maintenance resources busy; try again later
Form Input
After entering the command set options, the user i s presented with the following
form.
set options Page 1 of 8
ALARM REPORTING OPTIONS
Major Minor
On-board Station Alarms: w w
Off-board Station Alarms: w w
On-board Trunk Alarms (Alarm Group 1): y y
Off-board Trunk Alarms (Alarm Group 1): w w
On-board Trunk Alarms (Alarm Group 2): w w
Off-board Trunk Alarms (Alarm Group 2): w w
On-board Trunk Alarms (Alarm Group 3): w w
Off-board Trunk Alarms (Alarm Group 3): w w
On-board Trunk Alarms (Alarm Group 4): w w
Off-board Trunk Alarms (Alarm Group 4): w w
On-board Adjunct Alarms: w w
Off-board Adjunct Alarms: w w
Off-board DS1 Alarms: w w
Off-board PGATE-PT Alarms: w w
Off-board Alarms (Other): w w