DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-890GPTD-PT (General Purpose Tone Detector Port)

9
Tone Detector Audit/Update Test (#43)
The GPTD port is refreshed with all time slot information and sanity audit is performed on the GPTD port
Table 9-339. TEST #43 Tone Detector Audit/Update Test
Error
Code Test
Result Description/ Recommendation
ABORT The system was not able to allocate the resources needed for this test.
1. Wait 1 minute and try again.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL Hardware audit failed.
1. Run the Short Test Sequence: test port UUCSSpp short repeat 1.
2. If the problem persists, the system is still operating properly but system
capacity will be reduced. To restore the system performance to normal,
replace the Tone Detector circuit pack containing the defective GPTD port.
PASS The GPTD port has been successfully refreshed with its translation.