DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-95ANL-LINE, ANL-NE-L (8-Port Analog Line)
9
1018 ABORT The test was disabled via administration. The default for the Test? field is
y; thus, you may want to determine why this field has been set to ā€œnā€ on this
station (this may be due to the ringing application Test #48, which can be
customer or terminal disturbing).
1. To enable the test for a particular station, enter change station
extension and set the Test? field to y.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available. Either a system
allocation to get information about the port or to put the port into a service
state failed or the attempt to put the port in connection with a tone source
failed (this could be a tone-clock prob lem). The tone-clock and tone
detectors could be having a communic ation problem, for example , the
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The terminal equipment is not connected to the circ uit pack or the ringing
generator may have failed.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If
present, refer to the RING-GEN (analog ring generator) Maintenance
documentation.
3. Check all of the wiring between the station equipment and the switch.
Then, run the test again.
4. If the test still fails, the set may be defective. Check the set, and
replace it, if necessary.
5. Some terminal equipment (such as a modem) could fail even when it is
connected properly. If this is the case, disable the test using the
change station extension command (enter n into the Test? field).
Note that this action also disables Tests 6, 7, 161, and 35 on this port.
PASS The station is connected properly to the switch. This test may also pass if
no terminal equipment is connected and the terminal is located very far
from the switch. User-reported troubles on this port should be investig ated
by using other port tests, by examining station wiring, or by examining the
station.
Table 9-37. TEST #48 Station Present Test ā€” Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page