DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1185PE-BCHL (PRI Endpoint Port)
9
c. The PRI endpoint port has been busied out by busyout pri-endpoint
extension or busyout port UUCSSpp. No wideband call s can be ma de to
this port, although wide band calls can still b e made to other ports within
this PRI endpoint if they are in service.
d. The far-end terminal adapter c hanged its ISDN
service
state to either
out-of-service or maintenance. This may b e a temporary condition d ue to
testing of this port by the far-end terminal adapter
or
a hardware problem
with the port. Outgoing calls to the terminal adapter will not b e allowed
over the port, although c alls can still be made to other p orts that are in
service within the same PRI endpoint. To investigate the status of the port,
enter status pri-endpoint extension.
e. This error type indicates that the circ uit pack has been removed or ha s
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
f. These error types indicate a disagreeme nt between this switch and the
terminal adapter at the other end of the connection with regard to the
ISDN service state of the PRI endpoint port. The switch wi ll automatically
try to recover by per forming a service state audit. Use st atus
pri-endpoint extension to determine the state of the por t.
When running the Short Test Sequence, pay close attention to the results
of the Service State Audit Test (#256).
g. This port is not recognized b y the far-end terminal adapt er. Investigate the
PRI endpoint administration for both the switc h and the terminal adap ter,
and make sure they agree.
h. The Conference Circuit Test (#7) failed on this port. See Test #7 for repair
procedures.
i. The NPE Crosstalk Test (#6) failed on this port. See Test #6 for repair
procedures.
j. This error indicates a failure of the UDS1 Interface circ uit pack. The results
of the Signaling Link State Check Test (#255 in the short sequence) are
important.
k. Two Service State Audit attempts have failed (see Test #256). The port will
not be usable for any outgoin g calls to the terminal adap ter until the test
passes and the port st ate is changed to in-servic e. Incoming calls from
the terminal adapter
will
be accepted over this port, and other ports in the
PRI endpoint can still be used for b oth incoming and outg oing calls to and
from the terminal adapter.
l. Error Type 3585 app ears when the switch receives an ISDN RESTART
message for an ISDN port that is not idle. Since calls are not typically
cleared with the RESTART message, this error type may b e associated
with a dropped c all report from a user.