DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-393CLAN-BD (Control LAN Circuit Pack)
9
1. Refer to Congestion Query Test (# 600) for Abort and Fail Error
Codes.
n. Error Type 3073: Remote Socket Control Link (RSCL) or Link Status Test
(#1279) failed. This failure may be due to the
circuit pack
packet bus
packet interface c ircuit pack .
o. Error Type 3330: Critical failure in Packet Bus interface.
Below, Error Types correspond to descriptions.
1. Attempt to clear the alarm (reset board UUCS S).
2. If alarm persists, replace c ircuit pack.
p. Error Type 3586 and 3999: Switch removed hyperactive circuit pack that
reported threshold numb er of errors. One or more of the following
symptoms may be present:
Circuit pack po rt tests return NO BOARD.
List configuration comman d shows circuit pac k and ports are
installed properly
If: Then:
Active buffers exceed threshold, CLAN enters congested state.
If: Then:
RSCL disconnects at link level Link fails
Link cannot be reconnected quickly Switch raises MINOR alarm
1292 Internal hardware component failed
1293 Insane on-board auxi liary processor
If the switch detects: Then it:
1 error, Resets circuit pack.
2 errors in 15 minutes, Raises MINOR alarm.