1113 ABORT The signaling link between the switch and the endpoint or adjunct is down.
1. Use the test port PCSSpp long command to clear a ny errors which
prevent establishment of t he signaling link.
2. Examine the results of Test #626, which is executed with the command.
If this test aborts or fails, follow the repair procedure for the Signaling
Link Status Test.
3. Escalate problem if BRI Layer 3 Query Test continues to abort.
1139 ABORT The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long PCSSpp
command, and review the results of the BRI Port Local LAN Loop
Around Test to verify the repair.
1141 ABORT The PKT-CTRL is out-of-service.
1. Consult the repair procedure for PKT-CTRL (Packet Control Circuit
Pack) Maintenance documentation.
2. If Step 1 does not resolve the problem, escalate to the next tier.
1144 ABORT The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus in the PPN.
2. After completing Step 1, execute the test port long PCSSpp
command, and review the results of the BRI Port Local LAN Loop
Around Test to verify the repair.
Table 9-154. TEST #629 BRI Layer 3 Query — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page