DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-539DIOD-TRK (DIOD Trunk)
9
PASS This test passed. Translation information was successfully updated on the
circuit pack. User-reported troub les on this port should be investigated by
using other port tests and by examining trunk or external wiring. If the trunk is
busied out, the test does not run, but returns PASS. To verify that the trunk is
in-service:
1. Enter status-command to verify that the trunk is in-service. If the trunk is
in-service, no further ac tion is necessary. If the trunk is out-of-serv ice,
continue to Step 2.
2. Enter release-trunk command to put trunk back into in-service.
3. Retry the test command.
Table 9-222. TEST #36 Port Audit Update Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page