DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1535STO-DATA (Stored Data)
9
Any FAIL One or more of the 4 files chec ked was inconsistent wi th the file on the other
device.
1. Enter list configuration software to determine the inconsistent file. If a
file on tape is the older file, use backup disk to copy the disk file to the
tape. If a file on disk is older file, use restore disk to copy the tape file to
the disk.
2. If for some reason the list configuration software command does not
provide the necessary data:
a. Convert the error code to a set of failure numbers. The error code
returned by the test is the sum of one or more failure numbers listed
in the table at the beginning of this test description,
Tests 835 and 836 Failure Numbers
. Using that table, subtract the largest failure
number possible (so as to leave a positive remainder) from the error
code and note the associated inconsistency from the table. Continue
subtracting failure numbers from the remainder until the remainder is
0. The numbers subtracted represent the inconsistencies found.
b. Use the results of the four consistency tests (#833, #834, #835 and
#836) to determine the device with the incorrect files. If the files on
the tape are newer than the files on the disk, restore the disk from the
tape (restore disk). If the files on the disk are newer than the files on
the tape, backup the tape from its disk (backup disk).
PASS The files are consistent between the compared devices.
1. If other MSS errors are present, refer to the H-ADAPTR, TAPE, and DISK
sections.
Table 9-584. TESTS #835 and #836 Tape to Tape and
Disk to Disk Consistency Tests — Continued
Error
Code Test
Result Description/ Recommendation