DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1056MET-LINE (MET Line)
9
Table 9-419. TEST #62 MET Line Ringer Update Test
Error
Code Test
Result Description/ Recommendation
3 ABORT This port may have been busied out.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
present, release the port via release station <extension> and run the
test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABOR T Syste m resources required to run this test are not available. The port may be
busy with a valid call.
1. Use display port UUCSSpp to determine the station extension of the
port. Use status station to determine the service state of the port. If the
port is in use, wait until the port is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS Hybrid Station Ringer Update passed.
1. If complaints p ersist, investigate using other circuit pack tests, an d by
examining the terminal, wiri ng, and connections .
0NO
BOARD The test could not relate the internal ID to the port. This could be due to
incorrect translations, no board is inserted, an incorrect board is inserted, or
an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case, check
to ensure that there is a valid board inserted.
Continued on next page