DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-536DIOD-TRK (DIOD Trunk)

9
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the se lected time slot and never crosses over to time slots rese rved for other connections. If the NPE is not working correctly, one way and noisy connec tions may be observed. This test is usually only part o f a port’s long test seq uence and takes approximately 20 to 30 second s to complete.
Table 9-220. TEST #6 NPE Crosstalk Test
Error
Code Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Enter display port UUCSSpp to determine the trunk group/member
number of the port. Use the status trunk command to deter mine the
service state of the port. If the port is in use, wait until the port is idle before
testing.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1001 ABORT Could not allocate the nec essary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, repeat
test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some tone detectors may
be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals a maximum of
5 times.
1004 ABORT The port was seized by a valid c all during the test. The test has been aborted.
1. Enter display port UUCSSpp to determine the trunk group/member
number of the port. Use the status trunk command to deter mine the
service state of the port. If the port is in use, wait until the port is idle before
retesting.
2000 ABORT Response to the test was not received within the allowable time period.
Continued on next page