DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1129OPS-LINE (DS1 Off Premises Station Line)
9
1004 ABORT The test was aborted because the port was seized by a user for a valid call.
Use status station command to determine the service state of the port. If the
service state indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1020 ABORT The test did not run due to an an already existing error on the specific port or
due to a more general error on the circuit pack.
1. Examine the error log for existing errors against this port or the circuit pack
and attempt to diagnose the already existing error. (Error code 1793
indicates a problem with the DS1 interface board, and any problems on
the associated DS1-BD or UDS1-BD should be resolved first.)
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test aborts with error code 2000 again, run short test sequence on
the associated DS1-BD or UDS1-BD. If tests 138 through 145 on the
associated DS1-BD or UDS1-BD are also aborting with error code 2000,
hyperactivity on the board or facility is indicated. In this case, the
hyperactivity problem should be dealt with first.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any FAIL The test failed. This can be due to on-board or off-board problems. Off-b oard
prob lems of c oncer n includ e EXP-PN and EXP-INTF faul ts, TDM-BU S faults,
and faults associated with the tone detectors/tone generators. Clear all
off-bo ard problems before replacing the board. Keep in mind that a TDM-BUS
problem is usually the re sult of a faulty board connec ted to the backplane o r
bent pins on the backplane.
1. Resolve any TONE-BD and/or TONE-PT errors.
2. Retest when the faults from step 1 are cleared.
Table 9-449. TEST #6 NPE Crosstalk Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page