DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-42ALARM-PT (ALARM PORT)

9
Station Status and Translation Audits and
Updates Test (#36)
For an analog line port that is admini stered as an external alarm, this test is limited to updating the software with the switchhook state.
Table 9-17. TEST #35 Battery Feed Test
Error
Code Test
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
reporting an external d evice alarm.
1. Enter test external-device-alarm port UUCSSpp to determine if the port
is reporting an EXT-DEV failure before retesting.
2. When the port has no EXT-DEV failure, retry the command at 1-minute
intervals for a maximum of 5 times.
1004 ABORT The port received an EXT-DEV failure during the test. The test has been
aborted.
1. Enter test external-device-alarm port UUCSSpp to determine if the port
is reporting an EXT-DEV failure before retesting.
2. If the port has no EXT-DEV failure, retry the command at 1-minute
intervals for a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessa ry system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL The port’s battery feed chip is unab le to supply sufficient power to sense the
external device alarm. This may occur when the test is performed at the same
time that the external device contact closure occurred.
1. Enter test external-device-alarm port UUCSSpp to determine if the port
is reporting an EXT-DEV failure before retesting. Wait until the port has no
EXT-DEV failure before retesting.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
PASS The port’s battery feed chip is able to provide power to the external devic e
alarm to detect contact closure.
Continued on next page