DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1047MET-LINE (MET Line)
9
Table 9-415. TEST #56 MFAT Electronic Power Feed Test
Error
Code Test
Result Description/ Recommendation
ABORT The test was aborted due to an internal system error on a software request to
the board.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension of the port. Use the status station command to determine the
service state of the port. If the port is in use, wait until the port is idle before
testing.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
FAIL The test failed with an internal error while it was attempting to turn on the EPF.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS Electronic Power Feed Test passed. The message to turn on the power to the
station was successfully sent to the port.
1. Although this test will never actually return a FAIL result except for the
Internal system error described ab ove, it will log an error if the
overcurrent case is detected by the hardware. Check the Error Log for any
entries with Error Type 257 when the test has completed.
2. If Error Type 257 does not appear in the Error Log within 10 seconds after
completion of this test, it is safe to assume that the test sensed no
problems with the power to the station. You can verify that the station is
powered up correctly by executing a self-test on the station, and chec king
that all the feature buttons are op erating.
3. The appearance of Error Type 257 in the Error Log indicates a station
power problem. Check for a wiring short, a damaged jac k, a defective
voice terminal, or an incorrect type of terminal.