DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1096M/T-ANL (Maintenance/Test Analog Port)
9
Error Log Entries and Test to Clear Values
Notes:
a. This error code appears in the Error Log only if the MTB circuit pack has
been removed since the Error Log was last c leared. Verify that the circuit
pack has been reinser ted.
b. This error indicates a hardware failure on the Analo g Port circuitry.
Replace the Maintenance/Test circuit pac k if the alarm is not resolved by
the command above.
c. This error indicates that call p rocessing record s did not agree with
on-board records for the hook state (on-/off-hoo k) of the Maintenance/Test
Analog Port. This error is not se rvice-affecting and no action is required.
Table 9-435. M/T-ANL Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01 (a)
1. Run the Short Test S equence first. If all tests pass, run the Long Test S equence. Refer to the appropriate
test description and follow the recommended proc edures.
0 Any Any Any test port UUCSSpp
1 (b) 41018 none MINOR ON test port UUCSSpp l r 3
18 0 busyout port UUCSSpp WARNING OFF release port UUCSSpp
257 Any NPE Crosstalk test (#9) MINOR ON test port UUCSSpp l r 3
513 Any Analog Port Sanity Test
(#963) MINOR ON test port UUCSS01 r 2
769 Any Analog Port Digital
Looparound Test (#13) MINOR ON test port UUCSSpp r 3
3840(c) Any Hook State Inquiry test
(#566)